V34 Field Repairs and Troubleshooting |
|
CAUTION: Do not top off! Topping
off can lead to spills and splashes.
SPOUT REPLACEMENT
- Remove the clamp securing the Vapor Guard to the nozzle
using a pair of end cutting nippers.
- Slide the Vapor Guard off the spout.
- Loosen and remove the spout retaining nut using a
suitable wrench.
- Remove the spout with its vent tube from the nozzle body
using a slight twisting motion.
- Replace the square inner spout seal in the end of the
nozzle body.
- Slip the spout retaining nut over the new spout, insert
the spout gland into the nozzle body with the vent tube aligned with the vent tube hole.
Using a slight twisting motion seat the spout into the nozzle body. There will be a slight
resistance to the twisting of the spout if the vent tube in installed correctly. Thread
the spout retaining nut onto the body.
- Hold the spout straight and tighten the spout retaining
nut.
- Put a new clamp on the Vapor Guard and slide it over the
spout.
- Make sure THE SMALL HOLE in the Vapor Guard is located on
THE BOTTOM of the nozzle.
- Tighten the clamp firmly so that the Vapor Guard will not
rotate.
- Test the nozzle before returning to service.
|